Expertly Refurbished Chemistry Analyzers for Your Laboratory
At Northwest Lab Source, we have been happily supplying our customers with both used chemistry analyzers as well as refurbished chemistry analyzers for a number of years. We carry top name brands such as Abbott, Horiba ABX, Beckman, Mindray, Ortho Clinical, Roche, Siemens, Thermo Scientific and Tokyo Boeki.
We are confident you’ll find the right chemistry analyzer to perfectly suit your needs. These analyzers can be used for various applications including testing parameters for general chemistry, toxicology, sodium, chloride, potassium, and drugs of abuse. Whether you live in the United States or outside the U.S. borders, we offer shipping for both national and international purchases.
With our in-depth understanding and experience in the industry, you can rest assured you’ll be receiving high-quality products and first-rate customer service.
To learn more about our refurbished chemistry analyzers as well as our used chemistry analyzers, call us today.
CHEMISTRY ANALYZERS
The Piccolo Xpress allows healthcare providers to perform routine multi-chemistry panels using 0.1cc of whole blood, serum or plasma. The system uses patented reagent discs that contain up to 15 chemistry tests.
Specifications
Weight
Power Adapter
Power Requirements
Sample Size
Sample Type
Test Time
Quality Control Features
Communication
Consumables
Data Input Display
Printer
Memory Capacity
Mode of Opertion
Protection Against Ingress of Fluids
Analyzer Software
Analyzer Hardware
Ambient Operating Temperature Range
Reaction Temperature
Operating Humidity
Thermal Protection Rating
Maximizes testing throughput with high-quality assays to deliver efficient and accurate results for greater productivity.
Method: Photometric, Potentiometric
Sample Type*: Serum, plasma, urine, cerebrospinal fluid, hemolysate, whole blood
Sample Capacity: 150
Reagent Capacity: Up to 70
Maximum Throughput: Up to 1,350 tests/hour
UNIFORMITY
Standardize operations across your lab and network, and optimize your limited resources.
Intuitive, user-driven design simplifies touch points and interactions.
Easy-to-use graphic interface with common software and iconography provides a consistent experience.
FLEXIBILITY
Adapt to the day-to-day and long-term unpredictability of changing lab volumes.
Scalable design allows for module additions and system reconfiguration as needs change with growing testing volumes.
Multiple track-connectivity options provide open, customized automation for third-party systems to connect multiple departments across the lab and network.
OPERATIONAL PRODUCTIVITY
Address limited space and increasing demand with increased throughput and capacity.
Increased sample and reagent load-up capacity means more tests per square meter for maximized throughput resulting in a compact footprint.
Continuous reagent access maintains uptime without interruption to tests in progress for greater operational productivity.
CONFIDENCE
Provide consistent, high-quality service to physicians and reduce waste.
Error-proof design and proven technology provides accurate results across platforms.
Assay harmonization to Clinical and Laboratory Standards Institute guidelines ensures clear performance parameter definitions.
The ARCHITECT c4000 clinical chemistry analyzer demonstrates high-quality testing results and rapid STAT turnaround time. The ARCHITECT c4000 enhances laboratory productivity and provides users high confidence in clinical results.
The ARCHITECT c4000 offers a maximum throughput of up to 800 tests per hour. Featuring a load-up capacity of 100 samples with 35 priority positions, the ARCHITECT c4000 allows for up to 90 refrigerated reagent positions on board, plus Integrated Chip Technology (Na+, K+ and Cl-).
For in vitro diagnostic use only.
Methods | Photometric, Potentiometric, Turbidimetric |
Maximum Throughput | Up to 800 tests/hour |
Sample Types | Serum, Plasma, Whole Blood, Urine, CSF |
Sample Tubes |
Height: 72-102 mm Diameter: 9.6-16.1 mm |
Sample Cup | Yes (50 µl dead volume) |
Sample Capacity | 100 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | 1.5-35 µL, Average: 6 µL |
Automatic Dilution | Yes |
Sample Probe Carryover |
<1000 ppm WB to WB ≤0.1 ppm WB to Serum |
Reagent Capacity | Up to 90 refrigerated positions plus patented ISE (Na+, K+ and Cl-) |
Reagent Type | >95% liquid ready-to-use |
Reagent Onboard Stability | 5-65 days, Average: 40 days |
Calibration Frequency | 1-60 days, Average: 25 days |
Sample, Clot and Bubble Detection | Yes |
Reagent Pressure Monitoring | Yes |
Sample Interference Measurement | Yes: Hemolysis, Icterus, and Lipemia |
System Control Center | 1 SCC, with color touchscreen monitor, keyboard and mouse |
Onboard Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, host query option available |
Remote Diagnostics | AbbottLink |
Dimensions (H x W x D) |
49" x 63" x 36" 125.1 x 160 x 90.7 cm |
Weight |
1,132 lbs 513.5 kg |
Electrical Requirements | AC 180-264V, 47-63 Hz, 20 amp |
Water Requirements | Deionized water 15 liters/hour during normal operation, 25 liters/hour maximum |
Heat Output* | 3050 BTU/hr, running mode |
Sample Loading | RSH |
Consistent STAT turnaround time. Large load-up capacity. Minimal sample carryover.
The ARCHITECT c8000 clinical chemistry analyzer provides all these benefits to help you achieve excellent first-time results and fewer reruns. With the ARCHITECT c8000, you can have speed, certainty, and confidence in your clinical results.
The ARCHITECT c8000 offers a maximum throughput of up to 1,200 tests per hour. Featuring a load-up capacity of 215 samples with 35 priority positions, the ARCHITECT c8000 has up to 121 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).
Methods | Photometric, Potentiometric, Turbidimetric |
Maximum Throughput | Up to 1,200 tests/hour |
Sample Types | Serum, Plasma, Whole Blood, Urine, CSF |
Sample Tubes |
Height: 72-102 mm Diameter: 9.6-16.1 mm |
Sample Cup | Yes (50 µl dead volume) |
Sample Capacity | 215 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | 1.5-35 µL, Average: 6 µL |
Automatic Dilution | Yes |
Sample Probe Carryover |
<1000 ppm WB to WB ≤0.1 ppm WB to Serum |
Reagent Capacity | Up to 121 refrigerated positions plus patented ISE (Na+, K+ and Cl-) |
Reagent Type |
>95% liquid ready-to-use |
Reagent Onboard Stability |
5-65 days, Average: 40 days |
Calibration Frequency |
1-60 days, Average: 25 days |
Sample, Clot and Bubble Detection | Yes |
Reagent Pressure Monitoring | No |
Sample Interference Measurement | Yes: Hemolysis, Icterus, and Lipemia |
System Control Center | 1 SCC, with color touchscreen monitor, keyboard and mouse |
Onboard Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, host query option available |
Remote Diagnostics | AbbottLink |
Dimensions (H x W x D) |
48" x 79" x 49" 121.9 x 200.6 x 124.5 cm |
Weight |
1,425 lbs 646.4 kg |
Electrical Requirements | AC 180-264V, 47-63 Hz, 20 amp |
Water Requirements | Deionized water 25 liters/hour during normal operation |
Heat Output* | 3400 BTU/hr, running mode |
Sample Loading | RSH + Carousel |
Imagine being able to count on excellent results — not only in the first run, but in every run thereafter. That's what you can expect with the ARCHITECT c16000 clinical chemistry analyzer. The ARCHITECT c16000 offers high throughput to handle heavy workloads with certainty and confidence in all your results.
The ARCHITECT c16000 offers a maximum throughput of up to 1,800 tests per hour. Featuring a load-up capacity of 215 samples with 35 priority positions, the ARCHITECT c16000 has up to 130 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).
Methods |
Photometric, Potentiometric, Turbidimetric |
Maximum Throughput |
Up to 1,800 tests/hour |
Sample Types |
Serum, Plasma, Urine, CSF |
Sample Tubes |
Height: 72-102 mm Diameter: 9.6-16.1 mm |
Sample Cup |
Yes (50 µL dead volume) |
Sample Capacity |
215 |
Sample Barcode Types |
Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage |
50,000 |
Sample Volume |
1.5-35 µL, Average: 6 µL |
Automatic Dilution |
Yes |
Sample Probe Carryover |
≤0.1 parts per million |
Reagent Capacity |
Up to 130 refrigerated positions plus patented ISE (Na+, K+ and Cl-) |
Reagent Type |
>95% liquid ready-to-use |
Reagent Onboard Stability |
5-65 days, Average: 40 days |
Calibration Frequency |
1-60 days, Average: 25 days |
Sample, Clot and Bubble Detection |
Yes |
Reagent Pressure Monitoring |
Yes |
Sample Interference Measurement |
Yes: Hemolysis, Icterus and Lipemia |
System Control Center |
1 SCC, with color touchscreen monitor, keyboard and mouse |
Onboard Maintenance Records |
Yes |
Online Error Code Help |
Yes |
Host Interface |
Bidirectional, serial RS-232 interface, host query option available |
Remote Diagnostics |
AbbottLink |
Dimensions |
48" x 79" x 49" 121.9 x 200.6 x 124.5 cm |
Weight |
1,545 lbs 701 kg |
Electrical Requirements |
AC 180-264V, 47-63 Hz, 20 amp |
Water Requirements |
Deionized water ≤54 liters/hour during normal operation |
Heat Output* |
4730 BTU/hr, running mode |
Sample Loading |
RSH + Carousel |
The ARCHITECT ci4100 combines ARCHITECT c4000 and ARCHITECT i1000SR instruments − offering lower volume laboratories the enhanced efficiency and productivity employed by larger volume laboratories.
The ARCHITECT ci4100 offers a maximum throughput of up to 900 tests per hour, including 800 clinical chemistry and 100 immunoassay tests. Featuring a load-up capacity of 180 samples with 35 priority positions, the ARCHITECT ci4100 has up to 115 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).
Methods | See c4000 and i1000SR specifications |
Maximum Throughput | Up to 900 tests/hour |
Sample Types | See c4000 and i1000SR specifications |
Sample Tubes |
Height: 72-102 mm Diameter 9.6-16.1 mm |
Sample Cup | Yes (50 µL dead volume) |
Sample Capacity | 180 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | See c4000 and i1000SR specifications |
Automatic Dilution | Yes |
Sample Probe Carryover |
≤0.1 parts per million |
Reagent Capacity | Up to 115 refrigerated positions plus patented ISE (Na+, K+ and Cl-) |
Reagent Type | See c4000 and i1000SR specifications |
Reagent Onboard Stability | See c4000 and i1000SR specifications |
Calibration Frequency | See c4000 and i1000SR specifications |
Sample, Clot, and Bubble Detection | Yes |
Reagent Pressure Monitoring | See c4000 and i1000SR specifications |
Sample Interference Measurement | Yes: Hemolysis, Icterus, and Lipemia |
System Control Center | 1 SCC, with color touchscreen monitor, keyboard and mouse |
Onboard Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, host query option available |
Remote Diagnostics | AbbottLink |
Dimensions (H x W x D) |
49” x 111” x 36” 125.1 x 281.2 x 90.7 cm |
Weight | 1,677 lbs 760.7 kg |
Electrical Requirements | See c4000 and i1000SR specifications |
Water Requirements | See c4000 and i1000SR specifications |
Heat Output* | See c4000 and i1000SR specifications |
Sample Loading | RSH |
One platform. Multiple benefits. The ARCHITECT ci8200 combines the ARCHITECT c8000 and the ARCHITECT i2000SR to provide clinical chemistry and immunoassay testing in a single integrated system. By delivering fast, high-quality STAT results, the ARCHITECT ci8200 allows for laboratories to handle complex workloads.
The ARCHITECT ci8200 integrated system provides laboratories a single testing module that is specifically designed to improve laboratory efficiency and turnaround time. The ARCHITECT ci8200 offers a maximum throughput of up to 1,400 tests per hour, including 1,200 clinical chemistry and 200 immunoassay tests. Featuring a load-up capacity of 365 samples with 35 priority positions, the ARCHITECT ci8200 has up to 146 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-).
Reaction Method | See c8000 and i2000SR specifications |
Maximum Throughput | Up to 1,400 tests/hour |
Sample Types | See c8000 and i2000SR specifications |
Sample Tubes | Height: 72-102 mm Diameter 9.6-16.1 mm |
Sample Cup | Yes (50 µl dead volume) |
Sample Capacity | 365 |
Sample Barcode Types | Code 39, Codabar, Interleaved 2 of 5, Code 128 |
Sample Result Storage | 50,000 |
Sample Volume | See c8000 and i2000SR specifications |
Automatic Dilution | Yes |
Sample Probe Carryover | ≤0.1 parts per million |
Reagent Capacity | Up to 146 refrigerated positions plus patented ISE (Na+, K+ and Cl-) |
Reagent Type | See c8000 and i2000SR specifications |
Reagent Onboard Stability | See c8000 and i2000SR specifications |
Calibration Frequency | See c8000 and i2000SR specifications |
Sample, Clot and Bubble Detection | Yes |
Reagent Pressure Monitoring | See c8000 and i2000SR specifications |
Sample Interference Measurement | Yes: Hemolysis, Icterus, and Lipemia |
System Control Center | 1 SCC, with color touchscreen monitor, keyboard and mouse |
Onboard Maintenance Records | Yes |
Online Error Code Help | Yes |
Host Interface | Bidirectional, serial RS-232 interface, host query option available |
Remote Diagnostics | AbbottLink |
Dimensions |
48" x 127" x 49" |
Weight |
2,447 lbs |
Electrical Requirements | See c8000 and i2000SR specifications |
Water Requirements | See c8000 and i2000SR specifications |
Heat Output* | See c8000 and i2000SR specifications |
Sample Loading | RSH + Carousel |
Abbott I STAT 1, This revolutionary, handheld analyzer provides reliable test results in just minutes, using as little as two drops of blood and a test cartridge.
Lightweight, portable and easy to use, the i-STAT 1 blood analyzer operates with the advanced technology of single-use i-STAT test cartridges. Combined, they create the i‑STAT System — a blood analysis system that offers a broad menu of tests on a single, point-of-care platform, providing healthcare professionals with diagnostic information where and when it’s needed.
FAST, LAB-QUALITY RESULTS
Test with the patient in minutes – no delays caused by transporting samples to the lab or waiting on results
SIMPLE TO USE
Clear and comprehensive instructions help operator through the testing process
BROAD TEST MENU
Single-use i-STAT test cartridges cover a broad menu of testing options in a single platform
THE i-STAT SYSTEM CAN CONNECT TO MULTIPLE POC DATA MANAGEMENT SYSTEMS
Easily manage with-patient testing and the i-STAT System with a number of compatible data management software solutions. Data management solutions help you oversee test results, operators and devices and seamlessly integrate with your Laboratory Information System (LIS) and Electronic Medical Records (EMR).
Processing up to 285 tests per hour with both photometric and potentiometric detection technologies, the ACE Axcel helps physicians quickly diagnose and effectively monitor patients, delivers a reliable revenue stream for business, and eases and streamlines procedures for laboratory personnel.
Cleared by the FDA specifically for use in POLs, ACE Axcel makes in-house chemistry testing fast, convenient, and cost effective.
ACE Axcel Instrument Features
- Self-contained system in a small footprint; no dedicated waste disposal, water line, or cooling unit required
- Disposable cuvettes provide the highest level of accuracy and eliminate the need for a water system
- Gold standard blood gas electrode technology
- On-board reagent refrigeration maintains specimen and reagent integrity
- Liquid, ready-to-use reagents eliminate prep time
- Closed-tube sampling with the STEP module minimizes operator interaction with the sample, making for a safer workplace
The Beckman Coulter AU400e Chemistry Analyzer is a fully automated chemistry analyzer designed for operating ease, speed, and flexibility. It uses liquid, barcoded reagents and user-friendly Microsoft Windows software. The operator is assured a fast turnaround time for response panels, maximum 800 tests per hour with the ISE, 400 tests per hour photometric.
Fast and reliable turnaround times
- Up to 400 photometric tests per hour and up to 800 tests per hour with electrolytes.
- Immediate STAT interrupt with HCFA basic metabolic eight test panel results available within five minutes.
Walk away design saves operator time
- 80-sample rack loading for peak workloads
- 22-sample carousel for STAT
- Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric cups
- Mixed bar code capability
- Automated reflex and repeat testing
- Automated pre-dilution for urine and other specimens
Automated reagent handling
- Reagents are liquid and ready-to-use
- Barcoded cartridges provides on-board management (random placement, on-board stability and calibration tracking)
- All 76 R1/R2 reagent positions are open
- State-of-the-art Advanced Calibration stores up to 5 calibration curves per test
- Reagent Inventory predicts shortfalls by comparing on-board reagent versus average daily workloads
- Automatic changeover from empty to fresh bottle
Efficient review of results
- Choice of QC trending: Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots
- Search function to retrieve data by individual sample and type of test (up to 30,000 patient files)
- User-definable flags for abnormal results
Precision engineering for reliability and accuracy
- Capacitance liquid level detection to ensure accurate pipetting for reagents and specimens
- Clot detection and crash prevention for probes
- Exclusive spot photometric technology for precision optics
User-friendly Windows NT software simplifies training & operation
- Drop-down menus, icons, color-keyed graphics
- User Menu to customize operation
Operator's Guide with links, search, and bookmarks - Software capabilities support CLIA, NCCLS, and CAP compliance
- Computer-displayed maintenance videos
- Modem-linked Technical Support for access to Olympus experts
Maintenance: Automated for minimum operator time
- Programmable start-up
- Automated washes and checks
- Olympus dry-bath technology means no water bath maintenance
- Minimum disposables:
- Permanent glass cuvettes
- ISE electrodes are warranted for six months
- No sample or reagent tips to replace
With a throughput of 400 photometric tests per hour (up to 800 with electrolytes) and an on board capacity of 63 different analytes the AU480 Chemistry System is the ideal main analyzer for small to medium sized laboratories. The AU480 Chemistry System can also fit as a special chemistry or STAT analyzer in large laboratories as well. TheAU480 Chemistry System maintains many features of its predecessor the AU400 that made it successful; long life electrodes, low maintenance and superior spot photometer technology.
General Characteristics
Standardization
Only Olympus standardizes chemistry testing for low to very high-volume laboratories. This provides greater productivity, increased efficiency and lower cost for your lab.
Fast and reliable turnaround times
- Up to 400 photometric tests per hour and up to 800 tests per hour with electrolytes
- Immediate STAT interrupt that gives you basic metabolic eight test panel results within five minutes
Walk away design saves operator time
- 80-sample rack loading for peak workloads with continuous loading capability
- 22-sample STAT carousel
- Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric micro cup option
- Multiple bar code capability provides easier and faster calibration with lower cost
- Enhanced, reflex and repeat testing
- Automated pre-dilution for urine and other specimens
- Open design for direct connectivity to many lab automation systems
Automated reagent handling
- Reagents are liquid and ready-to-use
- Barcoded cartridges provide automated reagent management (on-board stability, expiration and calibration tracking)
- All 76 R1, R2 reagent positions are open for random cartridge placement
State-of-the-art Advanced Calibration stores multiple calibration curves per test - Reagent Inventory management alerts operator by comparing on-board reagent test volume versus average daily workload
Automatic changeover from empty to fresh bottle - Multiple sized reagent cartridges hold from 100 to 6000+ tests to meet the needs of the laboratory
Efficient review of results
- Choice of QC trending
Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots - Search function to retrieve data by individual sample and type of test (up to 100,000 patient files)
- User-definable flags for abnormal results
Precision engineering for reliability and accuracy
- Capacitance liquid level detection to ensure accurate pipetting for reagents and specimens
- Clot detection and removal for sample probes
- Crash protection for sample and reagent probes
Exclusive spot photometric technology for precision enhanced optics - Micro sampling capabilities for pediatric and other special samples
User-friendly Windows XP software: Helps reduce training time
- Single Screen system check: at-a-glance graphic dashboard for monitoring system status
- Universal descriptive icons and color-keyed graphics
- Customized User Menu: simplifies training and operation by staff
- Online Operator's Guide and video: reinforce training with links, search and bookmarks
- Software capabilities support CLIA, NCCLS and CAP compliance
- Computer-displayed maintenance videos
Web-based services: Eliminates paperwork and increases reliability
- Remote diagnostics for virtual on-site support
- Provides technical resource access, on-line product training with reagent ordering and tracking capability.
Maintenance: Automated for operational cost reduction
- Five (5) minutes average daily operator maintenance
- Programmable power-on and start-up
- Advanced calibration: stores up to five calibration curves per test
- Automated cleaning and system checks
- Olympus dry-bath technology means no water bath maintenance
- Minimum disposables:
- Permanent glass cuvettes
- ISE electrodes are warranted for six months
- No sample or reagent tips to replace
*Brand new Beckman AU 480 with installation, training, validation, and Service Contract included. We also carry reagents, controls, calibrators, wash solution and parts for all Beckman Analyzers.
*Put the power of versatility to work for your lab with a smart and efficient clinical chemistry analyzer solution. The AU480 chemistry analyzer is the ideal primary clinical chemistry analyzer for low- to mid-volume hospitals and laboratories, or dedicated specialty chemistry or STAT analyzer for larger laboratories. With throughput of up to 400 photometric tests per hour (up to 800 with ISEs), increased onboard testing, reduced sample volume and easy operation, the AU480 delivers efficiency for laboratories around the world.
The Beckman Coulter AU640e Automated Chemistry Analyzer is a fully automated chemistry analyzer designed for operating ease, speed, and flexibility. It uses liquid, barcoded reagents and user-friendly Microsoft Windows software. The operator is assured a fast turnaround time for response panels, maximum 1200 tests per hour with the ISE, 600 tests per hour photometric.
Standardization
Only Olympus standardizes chemistry testing for low to very high-volume laboratories. This translates to higher productivity, increased efficiency and greater cost savings for your lab.
Fast and reliable turnaround times
- Up to 800 photometric tests per hour and up to 1,200 tests per hour with electrolytes
- Immediate STAT interrupt with HCFA basic metabolic eight test panel results available within five minutes
Walk away design saves operator time
- 150-sample rack loading for peak workloads
- 22-sample carousel for STAT
- Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric cups
- Mixed bar code capability
- Automated reflex and repeat testing
- Automated pre-dilution for urine and other specimens
Automated reagent handling
- Reagents are liquid and ready-to-use
- Barcoded cartridges provide automated reagent management (on-board stability, expiration and calibration tracking)
- All 48 R1 and 48 R2 reagent positions are open for random cartridge placement
- State-of-the-art Advanced Calibration stores up to 5 calibration curves per test
- Reagent Inventory predicts shortfalls by comparing on-board
- reagent versus average daily workloads
- Automatic changeover from empty to fresh bottle
Efficient review of results
- Choice of QC trending
Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots - Search function to retrieve data by individual sample and type of test (up to 30,000 patient files)
- User-definable flags for abnormal results
Precision engineering for reliability and accuracy
- Capacitance liquid level detection to ensure accurate pipetting for reagents and specimens
- Clot detection and removal for sample probes
- Exclusive spot photometric technology for precision enhanced optics
User-friendly Windows XP software: Helps reduce training time
- Drop-down menus, icons, color-keyed graphics
- User Menu to customize operation
- Operator's Guide with links, search, and bookmarks
- Software capabilities support CLIA, NCCLS, and CAP compliance
- Computer-displayed maintenance videos
- Modem-linked Technical Support for access to Olympus experts
Maintenance: Automated for operational cost reduction
- Five (5) minutes average daily operator maintenance
- Programmable power-on and start-up
- Advanced calibration: stores up to five calibration curves per test
- Automated cleaning and system checks
- Olympus dry-bath technology means no water bath maintenance
- Minimum disposables:
- Permanent glass cuvettes
- No sample or reagent tips to replace
AU680 Chemistry System offers a speed of up to 1200 tests per hour and an on-board capacity of up to 63 different tests in parallel. The AU680 Chemistry System is operated through a new and highly intuitive graphical user interface, including embedded videos to support key maintenance steps.
General Characteristics
Standardization
Only Olympus standardizes chemistry testing for low to very high-volume laboratories. This provides greater productivity, increased efficiency and lower cost for your lab.
Fast and reliable turnaround times
- Up to 800 photometric tests per hour and up to 1200 tests per hour with electrolytes
- Immediate STAT interrupt that gives you basic metabolic eight test panel results within five minutes
Walk away design saves operator time
- 150-sample rack loading for peak workloads with continuous loading capability
- 22-sample STAT carousel
- Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric micro cup option
- Multiple bar code capability provides easier and faster calibration with lower cost
- Enhanced, reflex and repeat testing
- Automated pre-dilution for urine and other specimens
- Open design for direct connectivity to many lab automation systems
Automated reagent handling
- Reagents are liquid and ready-to-use
- Barcoded cartridges provides automated reagent management (on-board stability, expiration and calibration tracking)
- All 60 R1 and 48 R2 reagent positions are open for random cartridge placement
- State-of-the-art Advanced Calibration stores multiple calibration curves per test
- Reagent Inventory management alerts operator by comparing on-board reagent test volume versus average daily workload
- Automatic changeover from empty to fresh bottle
- Multiple sized reagent cartridges hold from 100 to 6000+ tests to meet the needs of the laboratory
Efficient review of results
- Choice of QC trending: Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots
- Search function to retrieve data by individual sample and type of test (up to 100,000 patient files)
- User-definable flags for abnormal results
Precision engineering for reliability and accuracy
- Capacitance liquid level detection to ensure accurate pipetting for reagents and specimens
- Clot detection and removal for sample probes
- Crash protection for sample and reagent probes
Exclusive spot photometric technology for precision enhanced optics - Micro sampling capabilities for pediatric and other special samples
User-friendly Windows XP software: Helps reduce training time
- Single Screen system check: at-a-glance graphic dashboard for monitoring system status
- Universal descriptive icons and color-keyed graphics
- Customized User Menu: simplifies training and operation by staff
- Online Operator's Guide and video: reinforce training with links, search and bookmarks
- Software capabilities support CLIA, NCCLS and CAP compliance
- Computer-displayed maintenance videos
Web-based services: Eliminates paperwork and increases reliability
- Remote diagnostics for virtual on-site support
- Provides technical resource access, on-line product training with reagent ordering and tracking capability.
Maintenance: Automated for operational cost reduction
- Five (5) minutes average daily operator maintenance
- Programmable power-on and start-up
- Advanced calibration: stores up to five calibration curves per test
- Automated cleaning and system checks
- Olympus dry-bath technology means no water bath maintenance
- Minimum disposables:
- Permanent glass cuvettes
- ISE electrodes are warranted for six months
- No sample or reagent tips to replace
*Brand new Beckman AU 680 with installation, training, validation, and Service Contract included. We also carry reagents, controls, calibrators, wash solution and parts for all Beckman Analyzers.
*AU680 Chemistry System offers a speed of up to 1200 tests per hour and an on-board capacity of up to 63 different tests in parallel. The AU680 Chemistry System is operated through a new and highly intuitive graphical user interface, including embedded videos to support key maintenance steps.
The Beckman Coulter AU2700 Chemistry system, formerly the Olympus AU2700, boasts over 95 assays with a maximum throughput of 1600 tests per hour. The AU family of systems are well regarded, open reagent, high quality chemistry systems that are considered one of the most popular chemistry systems on the market, in particular in the US laboratory marketplace.
Fast and reliable turnaround times
- Up to 1600 photometric tests per hour and up to 2133 tests per hour with electrolytes
- Immediate STAT interrupt with HCFA basic metabolic eight test panel results available within five minutes
Walk away design saves operator time
- 300-sample rack loading for peak workloads
- 22-sample carousel for STAT
- Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric cups
- Mixed bar code capability
- Automated reflex and repeat testing
- Automated pre-dilution for urine and other specimens
- Easy connectivity for automation
Automated reagent handling
- Reagents are liquid and ready-to-use
Barcoded cartridges provide on-board management (random placement, on-board stability and calibration tracking) - All 48 R1 and 48 R2 reagent positions are open for third-party reagent use
- Auto-calibration and auto-quality control
- Automatic changeover from empty to fresh bottle
- Multiple sized reagent cartridges hold from 100 to 6000+ tests to meet the needs of any size laboratory
- Minimal reaction volume of 120 µL reduces reagent consumption
- Reagent inventory tracking function predicts daily workloads
Efficient review of results
- Choice of QC trending: Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots
- Search function to retrieve data by individual sample and type of test (up to 60,000 patient files)
- User-definable flags for abnormal results
Precision engineering for reliability and accuracy
- Liquid level capacity detection to ensure accurate pipetting for reagents and specimens
- Clot detection and crash prevention for probes
- Exclusive spot photometric technology for precision optics
User-friendly Windows NT® software simplifies training and operation
- Drop-down menus, icons, color-keyed graphics
- User menu to customize operation
- Operator’s guide with links, search, and bookmarks
- Software capabilities support CLIA, NCCLS, and CAP compliance
- Computer-displayed maintenance videos
- Modem-linked technical support
Maintenance: Automated for minimum operator time
- Programmable start-up
- Automated washes and checks
- Dry-bath technology means no water bath maintenance
- Minimum disposables:
- Permanent glass cuvettes
- No sample or reagent tips to replace
Weight: 1,540 Lbs
Dimensions: 79 (W) x 45 (D) x 50 (H) inches
Give your high- and ultra-high-volume core laboratory a performance boost. Clinical chemistry analyzers in the AU5800 series are the fastest in the industry, processing up to 2,000 tests per hour with a full menu of assays, including Therapeutic Drug Monitoring (TDM) and Drugs of Abuse. Increase lab productivity with continuous operation, powerful throughput and scalable capacity up to four modules.
Continuous operation with minimal downtime and easy maintenance
- Complete replacement of sample and reagent probes, mixer bars, ISE and syringes in no more than three steps, no longer than 60 seconds
- Perform routine maintenance easily, minimizing startup time
Two Optional High-Speed ISE Units
- Single ISE with a maximum throughput of up to 900 tests/hr
- Dual ISE flow cell with a maximum throughput of up to 1,800 tests/hr
- Robust, long-life electrodes: warrantied for 6 months or 40,000 tests
- Electrodes can be replaced individually
- No preconditioning needed; electrodes are ready-to-use
Scalable capacity with a simplified and efficient workflow
- Increase testing capacity as needed with the modular design of the AU5800
- Connect up to four analytical modules depending on your volume requirements
- Simplify technologists' tasks with intuitive and easy-to-perform daily management procedures
Powerful throughput with reduced analytical turnaround time
- Maximize throughput with an intelligent sample management system that optimizes the processing of racks based on the tests ordered
- Ensure quick turnaround time for those critical patients with STAT priority testing and auto-repeat of abnormal results
- Configure your total laboratory solution with options to integrate AU5800 with pre-analytical automation, immunoassay and clinical IT
*Brand new Beckman AU 5800 with installation, training, validation, and Service Contract included. We also carry reagents, controls, calibrators, wash solution and parts for all Beckman Analyzers.
*With true random access capabilities and a throughput ranging from approximately 2,000 tests up to an impressive 9,800 tests per hour, the AU5800 is available in four different scalable models, positioned for the high-volume core hospital laboratory to the ultra-high-test volume commercial laboratory market segments.
The DxC 700 AU clinical chemistry analyzer is the latest innovation in a line of reliable chemistry systems for the mid- to high-volume laboratory. The DxC 700 AU combines the best-loved (and time-tested) features of the popular DxC and AU series of clinical chemistry analyzers. This powerful combination delivers maximal uptime, high reliability and precise performance.
Photometric Throughput: with ISE (tests/hour) 800/1,200 with ISE
Number of Onboard Assays: with ISE 63
Sample Volume (µL): 1.0-25.0
Sample Load Capacity: (Routine/STAT) 150 (15 racks x 10 samples), 22 samples by carousel
Clot Detection and Auto-clearing (Mechanism): Yes
Open Channel Capability: Yes
Software Windows: 7
*Brand new Beckman DXC 700 AU with installation, training, validation, and Service Contract included. We also carry reagents, controls, calibrators, wash solution and parts for all Beckman Analyzers.
*The DxC 700 AU clinical chemistry analyzer is the latest innovation in a line of reliable chemistry systems for the mid- to high-volume laboratory. The DxC 700 AU combines the best-loved (and time-tested) features of the popular DxC and AU series of clinical chemistry analyzers. This powerful combination delivers maximal uptime, high reliability and precise performance.
Photometric Throughput: with ISE (tests/hour) 800/1,200 with ISE
Number of Onboard Assays: with ISE 63
Sample Volume (µL) 1.0-25.0
Sample Load Capacity: (Routine/STAT) 150 (15 racks x 10 samples), 22 samples by carousel
Clot Detection and Auto-clearing (Mechanism) Yes
Open Channel Capability Yes
Software Windows 7®
The D-10 instrument provides comprehensive, fully automated hemoglobin testing in a compact footprint. Combining diabetes and β-thalassemia testing on a single platform, the system offers simple, efficient operation for clinics, physician offices or clinical laboratories. Easy to use, the D-10 includes an interactive instrument training CD-ROM and multi-lingual operational support.
The D-10 instrument provides comprehensive, automated hemoglobin testing in a compact footprint. Combining HbA1c and HbA2/F/A1c testing on a single platform, the system offers simple, efficient operation for clinics, physician offices, or clinical laboratories. Easy to use, the D-10 includes multilingual operational support.
Developed for flexibility and reliability, the D-10 features an automatic system startup checklist and touch screen operation. One-step cartridge switching, automatic sample bar code reading, remote support, interfacing with the laboratory information system (LIS), and the option to export the chromatogram all contribute to increased workflow efficiency. Whole blood primary tube sampling eliminates offline sample preparation. Separate programs for fast HbA1c or HbA2/F/A1c quantitation further simplify workflow. Onboard QC monitoring ensures reliable results. At only 15.8 inches (40.2 cm) wide by 21 inches (53.4 cm) deep by 19.5 inches (49.5 cm) high, the D-10 requires a minimum amount of laboratory space.
Review and print results through any network computer. Calibrated peaks are colored and all peaks are labeled to help make chromatograms easy to read.
This high-performance platform sets a new standard to aid clinicians in the diagnosis of patients living with diabetes, as well as monitoring existing patients. Deliver a full clinical picture in fewer steps with the D-10 System.
D-10 Rack Loader
Add capacity to the D-10 and streamline workflow with the D-10 Rack Loader and improved system software. Technicians can load up to 50 samples for walkaway analysis without user intervention, with the flexibility to load samples as they become available. Load all kit reagents at once, with no need to change buffer bottles in the middle of a kit. Flexibility is further enhanced with STAT sample processing.
D-10 Printer Installation Kit
Have results at your fingertips by including this option for a convenient thermal printer. Results and reports can be automatically or manually printed for immediate review.
The fully automated VARIANT II Hemoglobin Testing System is designed for high volume, featuring positive specimen identification, LIS interface, and complete, ready-to-use test kits for precise, accurate results.
This multi-analyte system requires no sample preparation and very little hands-on time by the operator. The sampling station accepts barcoded primary specimen tubes, reads the barcode, samples from the closed tube and dilutes and injects the specimen into the chromatographic station for analysis. Results are processed by Bio-Rad’s Clinical Data Management Software (CDM), which can interface with the laboratory information system (LIS) for real-time data transmission and superior data management. Bio-Rad provides complete assay kits for analysis of HbA1c and β-thalassemia on the VARIANT II analyzer.
Designed to the highest standards, the VARIANT II system is NGSP-certified, CE marked to meet the European IVD Directive and anchored to the Diabetes Control and Complication Trial (DCCT) reference study traceable to the IFCC Reference Method.
The VARIANT II TURBO Hemoglobin Testing System combines Bio-Rad’s HPLC precision and variant detection with fast throughput to provide a comprehensive solution for HbA1c testing. VARIANT technology provides a comprehensive solution for HbA1c testing. Built for exceptional performance, the state-of-the-art, fully automated VARIANT II Hemoglobin Testing System delivers quality results at high test volumes — providing results in 97 seconds per sample.
The VARIANT II Hemoglobin Testing System offers complete automation, with positive sample tracking and powerful data management. Save time and minimize errors with whole blood primary tube sampling — no costly manual preparation required. Streamline workflow through continuous or batch sampling. Results and chromatograms are captured and archived by Bio-Rad’s Clinical Data Management (CDM) software. CDM provides remote support and interfaces with laboratory information systems (LIS) for optimal data management. Advanced diagnostics, user alerts, and prompts reduce costs and training time, while the QC Module tracks quality control.
The Envoy 500+ performs approximately 490 tests per hour, allowing it to handle the workload of the busiest labs. The Envoy 500+ delivers the time and money saving features your lab requires with an integrated four-parameter dry ISE module, reusable glass cuvettes, positive sample and reagent identification, clot detection, liquid level sensing and many more.
Touch Screen
The Envoy® 500+ has a built-in LCD touch screen and is driven by the Windows® operating system. This provides greater ease of use and space savings by eliminating a bulky external monitor and CPU.
Quality Control
Quality Control results are stored in memory and easily displayed on the screen. QC can be evaluated using up to six Westgard rules and displayed with either the theoretical or calculated means.
Pre-Programmed Parameters
The Envoy reagent application parameters are pre-loaded into the software, saving you time and eliminating the possibility of data entry mistakes.
Large Capacity
The Envoy 500+ holds up to 40 individual Envoy reagents (mono or dual), providing a longer walk-away operation.
Refrigerated Reagent Tray
Onboard refrigeration and storage ensures reagent stability, which increases reliability of results, while lowering laboratory costs.
Continuous Inventory Monitoring
Continuous inventory monitoring enables the operator to know the number of tests remaining for each reagent, minimizing waste.
Positive Reagent Identification
The reagent chamber contains an infrared barcode scanner capable of scanning Envoy barcoded reagents, automatically recognizing reagent position and lot information.
Sample Wheel
The Envoy 500+ sample wheel has 52 positions available for patient samples and 26 for calibrators and controls providing your laboratory high throughput capability. Primary tubes or sample cups can be used, providing the testing flexibility you need.
Clot Detection and Liquid Level Sensing
Clot detection and Liquid level sensing prevents reporting of invalid results from an insufficient or difficult sample. This ensures accurate results and proper treatment decisions.
Positive Sample Identification
The sample chamber contains an infared barcode scanner, capable of scanning your patient barcodes, eliminating the need to manually enter patient information and reducing the risk of sample errors that can cost you time and money.
Dry Electrodes
The Envoy 500+ utilizes a proven, dry, solid-state ISE (Ion Selective Electrode) that can be kept dry when not in use thus reducing reagent consumption.
Four Parameters
The ISE system has four electrodes, Na+, K+, Cl- and CO2, providing a complete test panel without adding an enzymatic procedure or using a traditional ‘wet’ electrode. This significantly reduces costs and maintenance time, while increasing reliability of results.
Glass Cuvettes
The Envoy 500+ contains 34 reusable glass cuvettes that are automatically washed on board, which eliminates the cost of expensive disposable cuvettes.
Increased Walk-away Time
The reusable glass cuvettes also provide your lab longer walk-away time than a system using disposable cuvettes, which requires you to return to the instrument to reload cuvettes on a regular basis.
The ABX Pentra 400 is an extremely compact Clinical Chemistry benchtop analyzer. Its automation and continuous loading provides enhanced productivity in a user-friendly environment.
*Up to 420 tests per hour with the ISE module
*55 on-board assays with back-up availability
*Innovative cassette format
*Integrated work station and validation station
*Touch screen interface
*Real-time follow-up of your workflow
Overview
- 55 on-board assays
- Innovative cassette format
- Integrated workstation and validation station
- Touch screen
- Real-time viewing of your workflow
Features
- Analysis Method Types:
- Spectrophotometry: Colorimetry and Turbidimetry
- Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)
- Up to 55 assays on board
- Optional ISE Module (Na+, K+, Cl-)
- Maximum Throughput: 420 test/h
- FDA cleared
Sample Handling
- Sample Capacity: 6 racks with 10 sample positions for primary tubes or cups
- Continuous loading
- Positive Sample Identification: Integrated Barcode Reader and Tube Presence Detector
- Sample Integrity: Level, Shock and Clot Detection
- Sample Collection Format: 0.7, 4, 5, 7 and 10 mL (diameter: 16mm)
- Sample Specimen: Serum, Plasma, Urine, CSF, Whole Blood, Homogeneous Fluids
- Sample Volume: 2 to 380 µL
- Automatic Sample Dilution: from 1/2 to 1/22,500
- ISE: 10 µL (Indirect) or 65 µL (Direct)
- Automatic Post Concentration: from x2.0 to x 10.0
- Automatic Re-run
The Horiba Yumizen C560 clinical chemistry analyzer provides you with quick and reliable test results.
A standalone floor model analyzer, offering many high-end features typically found only in large integrated systems, the perfect workhorse for mid-size laboratories.
-High-quality barcode-packaged reagents
-Advanced, intuitive software
-Minimal maintenance
-Ease of access hardware design
System Function:
Fully automated, discrete, random access, with STAT sample priority capability
Throughput: 400 photometric tests/hour, up to 240 tests/hour for ISE
Measuring principles: Absorbance Photometry, Turbidimetry
Methodology: End-point, Fixed-time, Kinetic, ISE (Optional)
Single/Dual/Triple/Quadruple reagent chemistries, Monochromatic/Bichromatic
Programming: User defined profiles and calculation
Key features include:
Processes 1200 test/hour with ISEs
Dedicated STAT position
Random continuous access
Serum, Plasma and Urine samples
90 refrigerated reagent positions
61 dedicated refrigerated positions for calibrators and controls
Liquid level sensing
Clot detection
Cap/shock detection
Hemolysis, Icterus, Lipemia checks
Autoloader (optional accessory)
The Yumizen C1200 test menu includes the following panels:
Comprehensive Metabolic
Hepatic
Lipid
Renal
Anemia
Diabetes/ Stroke
Therapeutic Drugs (TDM)
Drugs of Abuse (DAU) and Adulterants
Specialty Assays
Inflammation/Allergy
BS-200 is a bench top, discrete and random access clinical chemistry analyzer with 200 tests per hour. It’s tailored for small laboratories (used as a main instrument); medium and big laboratories (used as a back-up instrument).
Features & Benefits:
- 200 tests per hour, up to 330 tests per hour with ISE (K, Na, Cl)
- 24-hour refrigeration for reagent tray
- Built-in barcode scanner
- Independent mixing stirrer
- Strong and friendly operation software
- Multi-language version is available
- Pre-dilution and post-dilution for sample
- Bi-directional LIS interface
Specifications
Light Source: Halogen-tungsten lamp
Photometer: Reversed optics, static fiber spot photometry
Wavelength: 340nm, 405nm, 450nm, 510nm, 546nm, 578nm, 630nm, 670nm
Absorption range: 0~4.0Abs (10mm conversion)
Resolution: 0.0001 Abs
Reaction rotor: Rotating tray, containing 80 cuvettes
Cuvette: Optical length 5mm
Reaction volume: 180-500ul
Reaction temperature: 37° C
Temperature fluctuation: ±0.1 °C
Throughput: Up to 225 tests per hour
Reagent/Sample tray: 40 positions for reagents and 40 positions for samples in refrigerated compartment (4~15° C)
Reagent volume: R1: 180-450µ1, step by 1 µI R2: 30~450µ1, step by 1 µI Sample volume: 3~45µ1, step by 0.5 µI
Reagent/Sample probe: Liquid level detection, collision protection and inventory checking
Probe cleaning: Automatic washing for both interior and exterior Carry-over < 0.1 %
Automatic sample dilution: Pre-dilution and post-dilution
Water consumption: 3.SL/hour
Dimensions: 34x27x46
Weight: 360 lbs
Power: 100-130V, 50/60 Hz, 1000 va
The Ortho Clinical Vitros 250 Chemistry System is a flexible system that can function as a single routine and STAT analyzer a dedicated system for STATs or esoterics or as a full-menu back-up to the VITROS 950. You get the same assay menu features and ease of use as the VITROS 950 plus on-board dilutions with a smaller footprint.
Efficient and productive in multiple environments
- Full menu backup to VITROS 950
- Small footprint
- Customized patient report for physician office laboratories
- Optional positive patient identification (PSID) enables LIS interfacing
- Automatic urine dilutions on-demand serum dilutions
- Up to 250 results/hour with 40 + on-board chemistries
Reliable high-quality results
- Provedn MicroSlide technology sets the standard for superior assay precision
- Minimal interference from hemolysis lipemia and bilirubin
- Fewer repeats redraws and dilutions than with wet chemistry systems
Checks and balances
- Short sample detection/clot detection/bubble detection – ensure accuracy
- Unique Smart Metering – ensures dependable testing integrity
- Disposable tips – ensure no carryover
- Continuous process verification – ensures the right result the first time
Easy to operate
- No deionized water no plumbing no drains
- Load bar-coded slide cartridges of any lot number in one easy step – with no reagent preparation
- Accepts any size primary/secondary containers or cups
- Small sample size requirements
- User-friendly help text is available at all times
- Biosafe operations with no infectious waste
Reduce your costs. Streamline your workflow
- Unit-dose test slides provide predictable operating costs
- Supports multiple slide lots on board at one time for better inventory control
- Low labor requirements
- QC once daily/up to 6-month calibration stability for most assays
- True random-access testing
The VITROS 350 Chemistry System offers easy operation, maintenance, and training. Whether you use it as a primary, STAT, or back-up to the powerful VITROS 5,1 FS, the VITROS 350 Chemistry System will get the job done right the first time. You know that VITROS Systems are efficient, dependable, and easy-to-use. The VITROS 350 comes complete with enhanced throughput, a broad accessible menu, and new ergonomic design. Boost your productivity and reduce costs with the system that delivers the right results the first time.
Key Features
- On board capacity for all 45 assays
- Sample types: serum, plasma, urine, CSF
- Sample volume: 5–11µL
- Sample capacity: 40 samples (4 trays of 10 samples)
- Time for single results: 2.5 to 8 minutes
- Primary tube sampling
- On board dilution
- Unique sample processing capabilities like disposable tips, bubble, and clot detection assure confidence in results
- Does not require deionized water, plumbing, or drains
- True random access testing
- Low-glare flat screen offers easy, touch-sensitive operation with enhanced ergonomics
- Wide, accessible on board menu delivers immediate results for STAT or routing testing and disease-focused panels
- Customized patient reports for physician office labs
Key Benefits
- High reagent efficiency
- “Load and Go” reagent preparation, MicroSlide™ technology, and up to six months' calibration stability mean labor can be redeployed for value-added tasks
- VITROS™ technology reduces interference from hemolysis, lipemia, and bilirubin
- Low cost per reportable result
- Minimal carryover and interference
- Minimal instrument maintenance
- Minimal chemical or infectious wastes reduce biohazards
- Self-monitoring alerts operators to prompt action avoiding testing delays
- Small footprint requires less space and overhead expenses
Reduce errors and increase result quality
Reduce error potential and increase result quality with proven, easy-to-use, self-monitoring VITROS® technologies. And address sample and reagent carryover and contamination concerns with single-use tips for sample and reagent metering that automatically verifies aspiration and dispense for clots, short samples, bubbles, and high and low fluid viscosity to avoid erroneous results.
Increase productivity to meet increased demand
Do more with less with a world-class immunoassay menu on a high-productivity platform. Minimize the need for operator interventions with an onboard capacity of 31 reagent packs and 3 bar-coded signal reagent packs. Improve your lab’s capacity to address peak workloads with productivity of up to 189 tests per hour1, a dedicated STAT lane for urgent and critical samples, and the ability to change reagents, consumables, and waste on the fly.
Streamline and standardize operations and workflow
Streamline your lab’s operations with standardization across VITROS® Systems and the flexibility to automate with a standardized, point-in-space interface and save resources with a system that uses no water and minimizes waste.
Improve results quality, evaluation, and trending
Increase confidence in result quality by eliminating carryover with the system’s disposable, single-use tip design. And improve result evaluation and trending ability within peer groups with configurable assay ranges that account for 7 demographic attributes for greater specificity.
Boost productivity while containing costs
Improve your productivity—and your budget—predictably with extended calibration times, uninterrupted walkaway operation, and less required maintenance. At the same time, tailor the instrument to your lab’s workflow with adjustable thresholds for onboard inventories, calibration expirations, and diluent volumes/expirations.
Simplify operations and streamline training and resources
Simplify the operation of your lab, streamline operator training, and boost workflow—while better managing costs—with the VITROS standardized User Interface. The interface also improves sample integrity traceability, while the editable maintenance log simplifies record keeping, allowing maintenance steps to be recorded directly on the system and reviewed or printed at the touch of a button.
Enabling Technologies
The VITROS® 5600 System leverages five of our patented core enabling technologies to maximize patient result quality, ease of use and productivity.
- VITROS® MicroSlide Technology delivers high-quality results with a 95% reportable result efficiency*— minimizing operator interventions and maximizing ease of use.
- VITROS® MicroTip Technology provides special chemistry menu offerings and user-defined assays in a cost-effective, easily implemented format.
- VITROS® MicroWell Technology features enhanced Chemiluminescence detection which enables wide dynamic ranges with exceptional immunoassay accuracy and precision across multiple disease states. Minimizes unnecessary dilutions, repeats and redraws.
- VITROS® MicroSensor Technology boosts efficiency and controls costs by automatically detecting and flagging endogenous interferences without compromising result turnaround or operator workflow.
- VITROS® Intellicheck® Technology delivers real-time process monitoring with fully documented traceability to minimize the risk of erroneous result reporting. The VITROS® 5600 System also offers a host of other design features that help ensure high quality results & system productivity, including:
- Disposable, Single-Use Tip Design, which eliminates carryover;
- SMART Metering, which checks for clots and bubbles every time the system aspirates or dispenses fluid to ensure the correct amount of fluid is used;
- Extended calibration times and less required maintenance;
- Continuous operator access for uninterrupted operation.
Powered by intelligent technologies and digital imaging technology, the Vitros XT 3400 system helps labs meet routine testing needs and with proven high-quality results and system reliability in a small footprint.
Manage up to 1,130 chemistry tests per hour thanks to the digital chemistry in the Vitros® XT 3400 system that provides improved performance and precision.
Only 74.8 µL of sample is required for a complete metabolic panel.
Because Vitros systems do not rely on water, you have greater flexibility to plan your lab layout.
VITROS XT 7600 Integrated System
The VITROS XT 7600 removes the obstacles to reducing turnaround time and increasing your ability to provide meaningful results.
-Maximum Uptime
Up to 6 months of calibration stability compared to non-VITROS® XT Systems.
-Reduced Sample Size to as low as 2.7uL
Improve patient care, particularly for populations whose sample is more precious.
-Greater Output
Doubling testing output from one MicroSlide without increasing your footprint.
-Digital Chemistry
Equipped with a new digital reflectometer, that improves accuracy.
-Streamlined Performance
Gain proactive and predictive data intelligence with informatic solution.
-Menu Expansion
Get the capability your lab needs today with scalability demands.
Have confidence in testing with accurate and reliable results from the RX daytona. The compact fully automated clinical chemistry analyser can provide rapid, cost effective testing for informed and dependable decisions, from the bench top to the bedside.
The RX daytona+ performs a wide range of niche and specialised routine chemistries, specific proteins, lipids, therapeutic drugs, antioxidants, diabetes and veterinary testing. The RX daytona+ also has testing Direct HbA1c testing capabilities eliminating sample pre-dilution and ultimately saving time in the laboratory. The RX daytona+ has the capability of analysing a variety of sample types including Serum, Plasma Urine, CSF and Whole Blood.
The RX daytona+ is a fully automated, random access platform delivering a high level of precision, accuracy and reliability with the ability to perform emergency STAT sampling. The most versatile analyser in its class, the RX daytona+ is capable of performing 270 photometric tests per hour and up to 450 with ISE testing.
The system comprises 72 semi-permanent reaction cuvettes lasting for 3-6 months with an economical reaction volume of between 100-350μl. The on-board cuvette checking function ensures only clean and viable reaction vessels are used.
50 positions are contained within the universal sample carousel, including 10 positions for calibrators and controls. The emergency loading port allows for the processing of STAT samples. Barcode sample identification ensures accurate matching of patient identification to specimen.
A thorough 12 stage washing process with acid, alkali and pure water wash steps eliminates contamination and carryover. Liquid level sensors at stations 1-5 prevent cuvette overflows.
Equipped with dual 5 speed stirrers, operators can choose the correct mixing speed depending upon the viscosity of the reagent, therefore optimising the mixing of each assay to ensure best performance.
System | 2nd Generation SWA: modular, analytical system platform, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site |
Types of modules |
|
Number of configurations |
7 module combinations; Up to 3 modules in one core unit
|
Sample throughput | Up to 120 racks/hour or 600 samples/hour |
Test throughput (theoretical max) |
|
Number of reagent channels (reagent slots) |
Up to 151 channels, in total 63 channels (including ISE, automatic setting) on cobas c 501 module 25 channels on cobas e 601 module |
Sample material | Serum, Plasma, Urine, CSF |
Core unit analytics |
|
Sample container types |
|
Sample volume | 1–35 µL |
Sample dilution | 3–121 times |
Sample clot detection | Available for cobas c 501 and cobas e 601 module |
Minimum sample volume |
|
Sample barcode types | Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39 |
System interfaces | RS 232 serial interface, bi-directional Interface to cobas link data station for cobas teleservice functionalities and automatic download |
Sample data base | 10.000 routine/STAT samples |
Test methods | For photometric modules: 1 point, 1 point + prozone check, 2 point, 2 point kinetic, 2 point + prozone check, 3 point, 1 point + kinetics Rate A, Rate A + serum index, Rate A with blank, Rate B |
Calibrator/QC input | Via specified racks through the input buffer or STAT port |
Calibration methods | Start-up, Re-calibration For photometric modules: Linear, non-linear multi-points, 2 point calibration, K-factor up to 100 different calibrators pre-programmable Storage of up to 180 curves Preventive calibration of the stand-by cobas c and cobas e packs on cobas c 501: Two k-factor can be defined for different sample types |
QC methods | For e- and photometric modules: Real-time QC, individual QC, cumulative QC Up to 100 controls pre-programmable Preventive QC after calibration of the stand-by cassettes/rack packs Auto QC: QC without operator intervention (timer triggered) |
Rerun/reflex function | Automatic rerun and manual rerun; Automatic reflex is supported by the system, reflex request to be provided by Roche Middleware Solutions |
Electrical requirements |
|
Water/waste requirements |
|
Water consumption |
|
Operational conditions |
|
Physical dimensions |
|
Weight |
|
From Roche Diagnostics, the Cobas C111 analyzer is designed for automated testing for small laboratories. Designed to deliver big analyzer performance With key components such as optics, reagents and calibrators taken from larger COBAS Integra and cobas blood gas systems used in reference labs and hospitals, the cobas c 111 analyzer joins a family of analyzers designed to deliver consistent results from the smallest to the largest system.
With a comprehensive test menu and easy integration of STAT samples, it can support testing of both routine clinical chemistry panels and rapid turnaround critical care markers. In addition, the cobas c 111 analyzer uses the same reagent formulations as the larger cobas® clinical chemistry analyzers. This standardizes patient results, which is vital to integrated laboratory networks serving outpatient services, emergency departments and clinics, as well as private laboratories serving primary care physicians.
High quality of results
- Comprehensive testing capabilities
- Results you can trust
Increased efficiency
- Essential routine testing on a small footprint
- Simplified system operation
Optimized workflow
- Reducing complexity for a range of laboratories, both networked or standalone
- Consistent results across the cobas platform
-
Excellent performance
- More than 40 assays and applications available including whole blood HbA1c, hsCRP, and D-dimer
High system reliability
- Robust system design
- Wizard-guided maintenance procedures
Good fit for labs <50 samples/day
- Throughput of up to 100 tests/hour
- Low water consumption of up to 3 liters per day
- Compact benchtop system for labs with limited floor space
- Easy, intuitive software handling
Network compatibility
- Ability to connect to local IT environment
- Common reagent chemistry across the cobas platform
First class performance
- Over 130 assays and applications available (including Direct Antiglobulin Tests (DATs), Therapeutic Drug Monitoring (TDM), specific proteins and whole blood HbA1c1
- Predictable turnaround time
Intelligent sample workflow
- 108 sample positions with continuous random access and flexible STAT priority settings1
- Automatic determination of sample integrity
- Automatic sample dilution and rerun capabilities
Unique reagent concept
- Convenient and error-free handling of cobas c packs
- No preparation or mixing required
- Economic usage with high stabilities and convenient kit sizes
High system reliability
- Highly reliable system based on more than 35 years of experience
- Automated maintenance functions
- Low system maintenance time
-
Product specifications
-
Testing capabilities
Clinical chemistry, ISE, HbA1c (whole blood measurement)
-
Throughput
Up to 300 tests/hr for photometry tests only
450 tests/hr for only ISE tests
-
Samples
Serum, plasma, whole blood, urine, cerebrospinal fluid (CSF), supernatant (hemolysate)
Automated sample rerun and dilution
Additional sample loading during operation
-
Test integrity measures
Contact-free ultrasonic mixing
Determination of 3 serum indices (lipemic, hemolytic, icteric)
Sample clot detection
-
Reagents
Up to 45 reagent positions (42 cassette positions and 3 channels for ISE)
Barcoded cobas c reagent packs
-
The COBAS Integra 400 Plus System delivers maximum versatility and ease of operation in a minimum amount of space. It combines the convenience and simplicity of load-and-leave reagent cassettes with an extensive test menu, as well as the proven reliability required to deliver effective, easy-to-use automation for both routine and STAT testing. The COBAS Integra 400 Plus System offers the flexibility to consolidate workstations in small- to medium-volume laboratories or to consolidate specialty tests in larger laboratories.
Economic efficiency
- Ready-to-use reagents with a long stability and low calibration effort
- Simplified processes and reduced costs
- Comprehensive testing capabilities on a compact footprint
Medical value
- Four measuring technologies: Absorbance photometry, Turbidimetry, Fluorescence polarimetry, Ion-selective electrode potentiometry
- Highly correlating results across all cobas® platforms
- Single-use cuvettes to ensure carry-over free analytics
Ease of use
- Comprehensive testing capabilities on a compact footprint
- Continuous loading and random access to samples
- Refrigerated storage for long calibration stability
The ADVIA 1200 system features a small footprint, which allows it to fit comfortably in any size laboratory. Capacity for 84 patient samples. Separate access to refrigerated area for on-board calibrators and controls. ~~Sampling system includes liquid level sensing, short sample detection and clot detection. The ADVIA 1200 system has minimal requirements for sample volume (as low as 1 µL/test).
Compact Size
The ADVIA® 1200 system features a small footprint, which allows it to fit comfortably in any size laboratory.
Productivity - Reliability - Expertise
Sample Tray
Capacity for 84 patient samples. Separate access to refrigerated area for on-board calibrators and controls.
Sample Probe
Sampling system includes liquid level sensing, short sample detection and clot detection. The ADVIA 1200 system has minimal requirements for sample volume (as low as 1 µL/test).
ISE System
Indirect Na+, K+, Cl-.Compact, easy to replace, long-life electrodes guaranteed for 30,000 tests per electrode.
Cuvette-based Reaction Tray Segmented tray for easy cuvette replacement. This advanced, high precision optical system combines with a unique incubation fluid and a concavity diffraction grating to ensure superior precision and accuracy in clinical chemistry instrumentation.
Reagent Storage Area
Refrigerated storage for 41 one- or two-reagent chemistries plus open system capability – providing total workstation consolidation.
The ADVIA® 1800 Clinical Chemistry System pushes the limit of productivity. Its extensive menu allows integration of testing for clinical chemistry, drugs-of-abuse, therapeutic drug monitoring (TDM) and specific proteins like Cystatin C and CardioPhase® hsCRP. The ADVIA 1800 Clinical Chemistry System offers:
- Throughput of up to 1,800 tests per hour provides speed to keep pace with workload peaks
- 200 basic metabolic panels per hour to meet turnaround-time demands
- Large onboard reagent capacity and optional concentrated reagents to reduce interruptions
- Optimal standardization of reagents and systems for efficient consumable usage
- Refrigerated onboard storage of controls and reagents for extended stability and increased productivity
- Automation ready design – no additional hardware required
Automation ready design
- Point-in-space aspiration offers connectivity to a track, VersaCell or rack handler without robotics or special hardware
- Redundant sample loading for built-in backup and easy handling of non-routine samples
- Direct sampling from track prevents detaining tubes at analyzer and reduces aliquoting
Peak productivity
- Throughput of up to 1,800 tests per hour provides the speed to keep pace with workload peaks
- 200 Basic metabolic panels per hour to meet turnaround-time demands
- Automatic Sample Retain technology provides the ability to perform reruns and dilutions without the need to retrieve primary tubes
- Consolidation power with a comprehensive menu, consistent cycle times, speed and open application capability
Total system reliability
- Minimal-maintenance ISEs
- Robust hardware and simplified software design, with automatic calibration validation and tracking
- Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion
- Direct water connection
- Remote diagnostics and ILQC (Inter-Laboratory Quality Control) options
Easy efficiency
- Large onboard reagent capacity and optional concentrated reagents reduce interruptions
- High-resolution touchscreen delivers push-button operation
- Reagent pause capability and onboard Sample Pause button make loading easy
- Minimal maintenance requirements, including no-maintenance oil bath
- Sample integrity checking, including serum indices reporting, short sample flagging and clot detection, reduces manual intervention
The ADVIA® 2400 Clinical Chemistry System manages the most demanding workloads and meets high turnaround-time (TAT) goals. Its menu includes methods for testing drugs-of-abuse, therapeutic drugs (TDM) and new assays such as Cystatin C and CardioPhase® hsCRP. The ADVIA 2400 Clinical Chemistry System offers:
- High throughput of up to 2,400 tests/hour (1,800 photometric and 600 ISE) to manage heavy workloads
- Rapid, consistent 2-second cycle time for faster tube speed and test throughput
- User-defined automatic repeat, dilution, and reflex testing
- Large onboard reagent capacity and optional concentrated reagents help to minimize intervention demands
- Refrigerated onboard storage of controls and reagents for extended stability and increased productivity
- Automation ready design – no additional hardware required
Superior Speed and Productivity
- Throughput of up to 2,400 tests/hour (1,800 photometric and 600 ISE) to manage the heaviest workloads
- Rapid, consistent 2-second cycle time
- Throughput of 200 tubes per hour even when running 3 ISE tests and 9 photometric tests per sample
- Automatic Sample Retain technology, auto-repeat, auto-dilution and auto-reflex testing
Automation Ready
- Point-in-space aspiration offers connectivity to a track or rack handler without robotics or special hardware
- Redundant sample loading for built-in backup and easy handling of non-routine samples
- Direct sampling from track prevents detaining tubes at analyzer and reduces aliquoting
Minimal Intervention Demands
- Minimal-maintenance ISEs
- Large onboard reagent capacity and optional concentrated reagents reduce interruptions
- No-maintenance 37°C incubation oil bath
- Auto-calibration and auto-QC from refrigerated onboard calibrators and controls
- Microvolume technology with 32,000 tests onboard and up to 60 days onboard stability improves walkaway time. Usage of concentrated reagents increases maximum capacity
- Remote diagnostics and ILQC (Inter-Laboratory Quality Control) options
Exceptional Reliability
- Sample integrity check for icterus, hemolysis and lipemia
- Sample probe with automatic clot/clog detection, liquid level sensing, short sample detection and crash protection
- Advances in reagent onboard stability, calibration frequency, interference reduction and assay linearity expansion
Features & Benefits
Atellica® Solution: flexible, scalable, automation-ready immunoassay and clinical chemistry analyzers featuring patented bidirectional magnetic sample-transport technology; the flexibility to create over 300 customizable configurations; and a broad assay menu with proven detection technologies.
Atellica® CH 930 Analyzer
- Clinical chemistry analyzer that runs up to 1800 tests per hour
- Photometric: 1200 tests per hour
- Integrated multisensor technology (IMT): 600 tests per hour
- Onboard capacity: 70 assays (67 reagent positions and three IMTs)
- Sample management via Atellica® Sample Handler or Atellica® Direct Load
- Up to six Atellica CH 930 Analyzers can be connected to accommodate chemistry testing volume
Atellica® IM 1600 Analyzer (high-volume)
- Mid-volume and high-volume options in the same footprint
- Atellica IM 1300 Analyzer: up to 220 tests per hour*
- Atellica IM 1600 Analyzer: up to 440 tests per hour*
- Proven acridinium ester (AE) technology
- 42 primary assay positions, 35 ancillary reagent positions
- Sample management via Atellica® Sample Handler or Atellica® Direct Load
- Up to three Atellica IM analyzers can be connected to the Atellica® Sample Handler to accommodate immunoassay testing volume
Atellica® Sample Handler
- High-capacity sample-processing component that sets the new standard in sample management
- >30 different sample container types accommodated
- Capacity: Up to 440 samples
- Throughput: Up to 500 samples per hour
- Multi-camera vision system with 360º view
- Automatic quality control and calibration
- 60 controls and calibrators stored in an onboard, covered, refrigerated compartment and shared by all connected analyzers
- Automated scheduling and delivery
- Up to three Atellica Sample Handlers can be integrated with up to seven Atellica® IM and CH analyzers
Atellica® Direct Load
- Sample processing component for a single Atellica® CH or IM analyzer
- Capacity: 60 tubes
- Throughput: 250 tubes per hour
The Dimension EXL 200 Integrated Chemistry System with patented LOCI Advanced Chemiluminescent Technology and automated productivity-enhancing features for both the low-volume laboratory and the STAT laboratory.
Trusted, proven technologies, including LOCI chemiluminescence, for fast and reliable results
Easy-to-use Dimension system provides the confidence that trained operators can run any test, any time
Chemistry and immunoassay integration allows simultaneous processing to maximize workflow efficiency
LOCI technology inside
Trusted results in a flash
Homogeneous chemiluminescent technology
Fast and accurate
Excellent precision
High sensitivity
Short reaction times, no washing or separation steps
Excellent STAT testing capability
Low sample volume required
True integration
Integration of chemistry and immunoassay with a comprehensive menu
One sample area
Common reagent area
Common reagent packaging
Trusted, proven technologies
LOCI advanced chemiluminescence
Heterogeneous Module
Photometry
QuikLYTE IMT
User-defined serum index (HIL) testing
Automation capabilities
Workflow efficiency
Process any test, any time, any shift
Plasma qualified assays
Fully automated onboard pretreatment (when required)
Fewer manual tasks
Automated calibration and control procedures
Infrequent calibration
Paperless, electronic data storage
Proactive STAT, sample, supply, QC and calibration alerts
No manual reagent preparation
No manual sample pretreatment
No limit or dedicated STAT positions required
The Dimension® EXL™ with LM Integrated Chemistry System gives you the power of both chemistry and immunoassay testing in one system, with a large onboard menu to increase workflow efficiency in low- to mid-sized laboratories.
- Simplify lab operations with an onboard capacity of 91 assays chosen from our comprehensive menu of chemistry and immunoassays.
- Improve workflow efficiency with the ability to test any tube, any place, any time, with no-pause sorting, no splitting tubes, and no shuttling between analyzers.
- Gain better outcomes with fast assay times for critical results, such as high-sensitivity troponin I in only 10 minutes, electrolytes in <1 minute, and automated-pretreatment immunosuppressive drug assays.
True Integration for Increased Efficiency
- Extend capabilities with a comprehensive menu, including chemistry, cardiac, thyroid, and our automated-pretreatment immunosuppressive drug assays.
- Avoid splitting samples—simultaneously run most assays from one sample tube.
- Simplify your workflow—mix and match chemistry and immunoassay tests on the fly in one common reagent area.
LOCI Technology Inside
- Experience excellent immunoassay sensitivity using small sample volumes with homogeneous LOCI® Advanced Chemiluminescence Technology.
- Produce fast and accurate results — assay times as short as 10 minutes for key critical assays.
High Productivity
- Increase testing capabilities with 91 assays onboard and the ability to load 18 reagents at once without pausing the system.
- Respond quickly with STAT sampling from any position and a 4-minute time to first result for a basic panel and electrolyte results in under a minute.
- Keep systems operating with only 5 minutes of daily maintenance and no daily hands-on maintenance for electrolytes.
This fully-automated random access benchtop system for clinical and specialty chemistry testing, combined with system reagents and consumables form a fully-supported, complete system solution offering confidence to daily work.
- IVD-compliant, cost-effective solution for small and medium laboratory settings
- Methods used in Indiko Plus are traceable to international reference methods and materials
- Sample oriented testing generates results quickly, enhancing the quality of patient care
- Application protocols include routine clinical chemistry tests as well as special tests, such as specific proteins, drug of abuse testing, therapeutic drug monitoring and immunosuppressant drug testing
- Simple and quick daily start-up and maintenance procedures
- Continuous access to samples, cuvettes and reagents without interrupting the testing process
- Disposable cuvettes allow user-safe and contamination free analysis
- Versatile, automated dilution features make sample processing easier
- Reflex testing capability offers savings in operator time, triggering automatically the specific test to be run
- Measurement reliability can be monitored with a real-time QC program
- Automatic upload of calibrator and control values save time and reduce manual errors
- Results archiving associated with calibration and reagent lot data secure full traceability
Specifications
- Operating Principle: Fully automated, sample oriented, random access analyzer
- Capacity: photometric tests/hr: up to 350 ; ISE tests/hr: up to 135
- On-board capacity: up to 108 sample positions and 42 reagent positions
- Sample volume: 2 to 120μL
- Reagent volume: 2 to 240μL (1 to 4 reagent additions/test)
- Reaction volume: 120 to 300μL
- Incubator: 9 x 10-position single-use cuvettes, totally 90 cuvette positions
- Photometer: 12 filter positions
- Absorbance range: 0 to 3.5A
- Water consumption: 2.5L/hr.
- Workstation: separate PC
- Bi-directional LIS-connection
- Power consumption: 300w
- Dimensions (L x W x H): 27.6 x 37 x 24.4in. (70 x 94 x 62cm)
- Weight: 242 lb. (110kg)
Run 240 tests per hour, handling up to 24 two-reagent immunoassays per run with the Thermo Scientific™ MGC 240 Benchtop Analyzer. This open, flexible system can be used for drugs of abuse screens and therapeutic drug monitoring including immunosuppressive diagnostic assays and specimen validity testing.
Features
- Broad menu of immunoassays with multiple technology options
- Multiple channels: up to 24 two-reagent tests
- High throughput: 240 tests/hour
- 24-hour reagent cooling
- Barcoding capabilities
Functions
- Random access, true STAT interrupt capability
- Adapts to various primary tubes and sample cups
- Automatic cuvette QC
- Auto rerun, auto dilution, sample pre-dilution
- Re-suspension mixing for latex particles
- Auto alarms for washing and waste containers
- Air pressure mixing: no carry over
Software
- Microsoft™ Windows™-based technology
Cuvettes
- Unique design
- Easy maintenance
- Distinctive air pressure mixing system: no mixing paddles
- No carry over: fewer washing steps
The BioLis 24i uses reusable cuvettes — this eliminates the need to purchase individual reaction cuvettes to be used with each test and eliminates cuvettes that need to be disposed of as hazardous waste. In addition, the Biolis 24i uses a water system, which eliminates the need for water cubes and their additional costs storage space. The Biolis 24i is also compatible with most LIS systems, which eliminates the need for paper documents.
The BioLis 24i performs over 400 tests per hour and has a menu of more than 100 tests, including a direct Drugs of Abuse, whole blood HbA1c, Homocysteine and GlycoMark.
This chemistry analyzer can be used as a bench top for a physician laboratory or as a back up or special chemistry analyzer in a hospital or reference laboratory. With its comprehensive menu, the chemistry analyzer is excellent for use in pain clinics, and endocrinology and oncology practices.
The combination of speed and menu for the BioLis 24i can not be touched by competitive systems. As an exceptionally easy-to-use chemistry analyzer, this means you will have the ability to make diagnoses more quickly, receive patient results the same day, and adjust medication in real time.
The BioLis 24i performs general chemistries tests — CMP, BMP, lipids, electrolytes, renal panels and liver panels — and special chemistries tests including Homocysteine GlycoMark,HbA1c,D Dimer,Cystatin C,LDL Direct,Lp(a),hsCRP,PLAC Test,Fructosamine etc.
Features
- Discrete, random access, fully automated
- 400 tests per hour
- 100 chemistry tests available
- Requires no disposable cuvettes
- Barcoded sample tubes and reagents
- Barcoded ready-to-use reagents
- Bidirectional interface with host query
- Electrolytes by ion selection electrodes
- 30-day onboard reagent stability
- 14-day calibration stability (most analytes)
- 24-hour reagent cooling
- Less operational noise
- STAT capabilities
- Wavelength 340-800 nm
- Automatically tracks reagent stability and position
- Controls assayed for Carolina Chemistries reagents with peer group survey
- Remote diagnostics
For small and medium size laboratories
for routine and special chemistry
Product specifications
- user friendly hardware and software
- real time display of analysis process, reagent residual volume
- cost effective
- 240 tests/hour, 400 tests/hour including ISE
- simple reagent management
- flexible - over 100 parameters available
- high precision - individual probes for reagent 1 and reagent 2 and sample
- no carry over - air pressure mixing system
- low noise
- low sample volume
- sample predilution and auto rerun dilution
- STAT operation
Specifications
Analysis
Method
Discrete, single-line random access, multi-test analysis
Types of analysis
max. 36 items + ISE 3 items or 24 items + ISE 3 items
Throughput
240 tests/h; 400 tests/h with ISE
Sample
Sample types
Serum, plasma, urine, CSF
Sample container
Sample cup, primary tube (5mL, 7mL, 10mL)
STAT loading
STAT sample loading available
Sample barcode
Optional
Reagent
Bottles on board: 72 (36 test items) or 48 (24 test items)
Reagent refrigeration: Available (24-h cooling)
Remaining reagent check
Liquid surface sensor or countdown system
Reaction
Reaction liquid volume: 140~400 μL
Reaction time: 10 min (first reaction 5 min, second reaction 5 min)
Wavelength: 12 fixed wavelengths (340~800 nm)
Purified water consumption: max. 3.5 L/h
Installation
Condition
Dimensions: 800 (W) 670 (D) 520 (H) mm
Weight: 95 kg (approx.)
Electrical requirements: AC 100/115/230 V, 50/60 Hz
For medium size laboratories and as backup for larger laboratories for routine and special chemistry
- Routine Clinical Chemistry
- Specific proteins
- TDM
- DoA
- ISE
Product specifications
- Clot detection and automatic cleaning
- QC sample cooling
- Carry-over protection program for cuvettes and probes
- Pre-dilution
- auto-rerun
- five mixing speeds
- water purification system built into the analyzer
- direct measurement of HbA1c
Specifications
Analysis
Method
Discrete, single-line random access, multi-test analysis
Types of analysis
max. 36 items + ISE 3 items
Throughput
480 tests/h; 580 tests/h with ISE
Sample
Sample types
Serum, plasma, urine, CSF
Sample container
Sample cup (0.5mL, 1.5mL)
Primary tube (2mL, 5mL, 7mL, 10mL)
STAT loading
STAT sample loading available
Sample barcode
Optional
Reagent/
Number of bottles on board
R1, 36 positions; R2, 35 positions
Reagent refrigeration
Available (24-h cold cooling)
Remaining reagent check
Liquid surface sensor or countdown system
Reaction
Reaction liquid volume: 120~300 μL
Reaction time
3.5 min from sample introduction + 5 min after dispending R2
Wavelength
12 fixed wavelengths: (340~800 nm)
Purified water consumption: max. 13 L/h
Installation
Condition
Dimensions: 1050 (W) 750 (D) 1145 (H) mm
Weight: 290 kg (approx.)
Electrical requirements: AC 100/115/230 V, 50/60 Hz
Touch Screen
The Envoy 500 has a built-in LCD touch screen and, is driven by the Windows® 2000 operating system. This provides greater ease of use and space savings by eliminating a bulky external monitor and CPU.
Quality Control
Quality Control results are stored in memory
and easily displayed on the screen. QC can be evaluated using up to six Westgard rules and displayed with either Levey-Jennings Graphs or Juden Plots.
Pre-Programmed Parameters
The Envoy Reagent application parameters are pre-loaded into the software, saving you time and eliminating the possibility of data entry mistakes.
Large Capacity
The Envoy 500 holds up to 40 individual Envoy reagents (mono or dual), providing a longer walk-away operation.
Refrigerated Reagent Tray
Onboard refrigeration and storage assures
reagent stability, which increases reliability of
results, while lowering laboratory costs.
Continuous Inventory Monitoring
Continuous inventory monitoring enables the operator to know the number of tests remaining for each reagent, minimizing waste.
Positive Reagent Identification
The reagent chamber contains an infrared
barcode scanner capable of scanning Envoy
bar coded reagents, automatically recognizing reagent position and lot expiration intervals.
Sample Wheel
The Envoy 500 sample wheel has 52 positions available for patient samples and 26 for calibrators and controls providing your laboratory high throughput capability. Primary tubes or sample cups can be used, providing the testing flexibility you need.
Liquid Sensor Detection
Liquid sensor detection prevents reporting of invalid results from an insufficient sample.
This ensures accurate results and proper
treatment decisions.
Positive Sample Identification
The sample chamber contains an infrared
barcode scanner, capable of scanning
your patient barcodes eliminating the need
to manually enter patient information and
reducing the risk of sample errors that can
cost you time and money.
Dry Electrodes
The Envoy 500 utilizes a proven, dry,
solid-state ISE (Ion Selective Electrode)
that doesn’t need to be kept wet, reducing
reagent consumption.
Four Parameters
The ISE system has four electrodes, Na+,
K+, Cl- and CO2, providing a complete
test panel without adding an enzymatic
procedure or using a traditional ‘wet’
electrode. This significantly reduces costs
and maintenance time, while increasing
reliability of results.
Glass Cuvettes
The Envoy 500 contains 34 reusable glass
cuvettes that are automatically washed
on board, which eliminates the cost of
expensive disposable cuvettes.
Increased Walk-away Time
The reusable glass cuvettes also provide
your lab longer walk-away time than a
system using disposable cuvettes, which
requires you to return to the instrument
to reload cuvettes on a regular basis.